{"product_id":"ingco-600a-ac-dc-digital-clamp-meter-premium-6000-counts-true-rms-display-dual-impedance-lowz-mode-and-vfd-lpf-signal-filtering-dcm66002","title":"INGCO 600A AC\/DC Digital Clamp Meter – Premium 6000 Counts True RMS Display, Dual-Impedance LowZ Mode, and VFD LPF Signal Filtering (DCM66002)","description":"\u003cp data-path-to-node=\"4\" id=\"p-rc_feb6c6b798123857-270\"\u003eDiagnosing complex electrical systems, tracking down transient voltage spikes, or measuring erratic current loads on industrial motor drives using standard multimeters is both slow and hazardous. Standard meters require you to break the circuit to measure current, which increases the risk of arc flash incidents and interrupts critical system operations. \u003cb data-path-to-node=\"4\" data-index-in-node=\"356\"\u003e\u003cspan class=\"citation-758 citation-end-758\"\u003eThe INGCO DCM66002 600A AC\/DC Digital Clamp Meter is a high-performance, professional testing instrument engineered to deliver safe, non-contact measurements in heavy-duty environments.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/b\u003e Outfitted with robust clamp jaws, this advanced diagnostic tool allows industrial electricians, HVAC technicians, and plant maintenance engineers to clamp directly around live conductors and instantly read both AC and DC currents up to 600A without interrupting the power flow. \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\" id=\"p-rc_feb6c6b798123857-271\"\u003e\u003cspan class=\"citation-757\"\u003eThe exceptional diagnostic precision and safety of this clamp meter stem from its \u003c\/span\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"82\"\u003e\u003cspan class=\"citation-757 citation-end-757\"\u003ehigh-accuracy 6000-count True RMS display and integrated Dual-Impedance LowZ mode.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/b\u003e Unlike cheap meters that struggle with distorted waveforms, the True RMS engine processes clean, accurate readings on both linear and non-linear electrical loads. \u003cspan class=\"citation-756 citation-end-756\"\u003eBuilt to prevent false readings caused by \"ghost voltages\" in parallel lines, the LowZ function introduces a low input impedance path to drain stray charges.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e To ensure reliable performance when servicing variable frequency drives (VFDs) and high-power motor installations, the meter features an \u003cb data-path-to-node=\"5\" data-index-in-node=\"623\"\u003eintegrated Low-Pass Filter (LPF) and an Inrush Current capture mode\u003c\/b\u003e. This allows you to filter out high-frequency noise during voltage tests and accurately record sudden motor startup currents. \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e6000 Counts True RMS Accuracy\u003c\/b\u003e – Delivers highly accurate readings on complex AC\/DC circuits, even when dealing with harmonic distortions or non-linear wave patterns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\" id=\"p-rc_feb6c6b798123857-272\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eNon-Contact 600A AC\/DC Clamp Jaws\u003c\/b\u003e \u003cspan class=\"citation-755 citation-end-755\"\u003e– Measures high-amperage lines safely and instantly without cutting wires or breaking the active circuit.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eDual-Impedance LowZ Mode\u003c\/b\u003e – Eliminates ghost voltage interference to prevent false readings and ensure ultimate measurement reliability in crowded electrical panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eVFD Low-Pass Filter (LPF)\u003c\/b\u003e – Advanced signal filtering strips away high-frequency noise and harmonics, allowing for clean AC voltage readings on variable frequency motor drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eInrush Current Measurement\u003c\/b\u003e – Accurately captures and locks the maximum startup current spike when heavy-duty machinery and industrial motors are first switched on.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\" id=\"p-rc_feb6c6b798123857-273\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eBuilt-In Non-Contact Voltage (NCV)\u003c\/b\u003e \u003cspan class=\"citation-754 citation-end-754\"\u003e– Includes an integrated sensor that safely detects the presence of live AC voltage through walls, outlets, and insulation without contact.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eBrand:\u003c\/b\u003e INGCO\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\" id=\"p-rc_feb6c6b798123857-274\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e \u003cspan class=\"citation-753 citation-end-753\"\u003eDCM66002\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\" id=\"p-rc_feb6c6b798123857-275\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eProduct Type:\u003c\/b\u003e \u003cspan class=\"citation-752 citation-end-752\"\u003eProfessional Industrial AC\/DC Digital Clamp Meter\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\" id=\"p-rc_feb6c6b798123857-276\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eDigital Display:\u003c\/b\u003e \u003cspan class=\"citation-751 citation-end-751\"\u003e6000-Count High-Contrast True RMS Screen\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\" id=\"p-rc_feb6c6b798123857-277\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003eAC\/DC Current Measurement Range:\u003c\/b\u003e \u003cspan class=\"citation-750 citation-end-750\"\u003e60A \/ 600A\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-path-to-node=\"11,5,0\" data-index-in-node=\"0\"\u003eAC\/DC Voltage Measurement Range:\u003c\/b\u003e 600mV \/ 6V \/ 60V \/ 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,6,0\" id=\"p-rc_feb6c6b798123857-278\"\u003e\u003cb data-path-to-node=\"11,6,0\" data-index-in-node=\"0\"\u003eResistance Measurement Range:\u003c\/b\u003e \u003cspan class=\"citation-749 citation-end-749\"\u003e600Ω \/ 6kΩ \/ 60kΩ \/ 600kΩ \/ 6MΩ \/ 60MΩ\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,7,0\" id=\"p-rc_feb6c6b798123857-279\"\u003e\u003cb data-path-to-node=\"11,7,0\" data-index-in-node=\"0\"\u003eCapacitance Measurement Range:\u003c\/b\u003e \u003cspan class=\"citation-748 citation-end-748\"\u003e10nF \/ 100nF \/ 1000nF \/ 10uF \/ 1000uF \/ 10mF \/ 100mF\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,8,0\" id=\"p-rc_feb6c6b798123857-280\"\u003e\u003cb data-path-to-node=\"11,8,0\" data-index-in-node=\"0\"\u003eFrequency Measurement Range:\u003c\/b\u003e \u003cspan class=\"citation-747 citation-end-747\"\u003e10Hz \/ 100Hz \/ 1000Hz \/ 10kHz \/ 100kHz \/ 1000kHz \/ 10MHz\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,9,0\"\u003e\u003cb data-path-to-node=\"11,9,0\" data-index-in-node=\"0\"\u003eTemperature Probe Range:\u003c\/b\u003e -40.0°C to 1000.0°C (-40.0°F to 1832.0°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,10,0\" id=\"p-rc_feb6c6b798123857-281\"\u003e\u003cb data-path-to-node=\"11,10,0\" data-index-in-node=\"0\"\u003eInput Impedance:\u003c\/b\u003e \u003cspan class=\"citation-746 citation-end-746\"\u003e10MΩ (Standard mode) \/ 300 kΩ (LowZ mode)\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,11,0\" id=\"p-rc_feb6c6b798123857-282\"\u003e\u003cb data-path-to-node=\"11,11,0\" data-index-in-node=\"0\"\u003eIntegrated Functions:\u003c\/b\u003e \u003cspan class=\"citation-745 citation-end-745\"\u003eNCV, Data Hold, LowZ, LPF (VFD), Inrush Current, Phase Function, Diode Test\u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,12,0\" id=\"p-rc_feb6c6b798123857-283\"\u003e\u003cb data-path-to-node=\"11,12,0\" data-index-in-node=\"0\"\u003ePower Source:\u003c\/b\u003e \u003cspan class=\"citation-744 citation-end-744\"\u003e3 x LR03 AAA Batteries (Included in package)\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,13,0\" id=\"p-rc_feb6c6b798123857-284\"\u003e\u003cb data-path-to-node=\"11,13,0\" data-index-in-node=\"0\"\u003eStorage Protection:\u003c\/b\u003e \u003cspan class=\"citation-743 citation-end-743\"\u003eHeavy-Duty Hard Plastic Carry Box\u003csup class=\"superscript\" data-turn-source-index=\"16\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eIdeal For\u003c\/h3\u003e\n\u003cp data-path-to-node=\"14\" id=\"p-rc_feb6c6b798123857-285\"\u003e\u003cspan class=\"citation-742 citation-end-742\"\u003eIndustrial electrical contractors, commercial HVAC\/R technicians, solar power installers, and industrial maintenance personnel who require a highly accurate, rugged, and feature-rich 600A AC\/DC clamp meter to safely troubleshoot complex machinery and electrical panels.\u003csup class=\"superscript\" data-turn-source-index=\"17\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"16\"\u003ePackage Includes\u003c\/h3\u003e\n\u003cp data-path-to-node=\"17\" id=\"p-rc_feb6c6b798123857-286\"\u003e\u003cspan class=\"citation-741 citation-end-741\"\u003e1 x INGCO DCM66002 AC\/DC Digital Clamp Meter\u003csup class=\"superscript\" data-turn-source-index=\"18\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\" id=\"p-rc_feb6c6b798123857-286\"\u003e1 x Set of Premium Color-Coded Test Leads\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\" id=\"p-rc_feb6c6b798123857-286\"\u003e1 x Specialized Temperature Probe K-Type Thermocouple\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\" id=\"p-rc_feb6c6b798123857-286\"\u003e\u003cspan class=\"citation-740 citation-end-740\"\u003e3 x LR03 AAA Alkaline Batteries\u003csup class=\"superscript\" data-turn-source-index=\"19\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\" id=\"p-rc_feb6c6b798123857-286\"\u003e\u003cspan class=\"citation-739 citation-end-739\"\u003e1 x Durable Protective Plastic Storage Case\u003c\/span\u003e\u003c\/p\u003e","brand":"FAST CLICK","offers":[{"title":"Default Title","offer_id":48755984367848,"sku":"DCM66002","price":2375.0,"currency_code":"MUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0781\/7648\/5608\/files\/DCM66002.jpg?v=1784194831","url":"https:\/\/www.fastclick.mu\/products\/ingco-600a-ac-dc-digital-clamp-meter-premium-6000-counts-true-rms-display-dual-impedance-lowz-mode-and-vfd-lpf-signal-filtering-dcm66002","provider":"FAST CLICK","version":"1.0","type":"link"}